Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Int J Implant Dent ; 10(1): 7, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38329586

RESUMO

PURPOSE: Maxillary molars have low alveolar bone height diameter due to the presence of the maxillary sinus; thus, a sinus lift may be required in some cases. Changes in the volume of bone substitutes can affect the success of implant therapy. Therefore, this study aimed to compare the changes in the volume of two different bone substitutes-one based on carbonate apatite and the other on octacalcium phosphate-used in maxillary sinus floor elevation. METHODS: Nineteen patients and 20 sites requiring maxillary sinus floor elevation were included in the study. Digital Imaging and Communications in Medicine data for each patient obtained preoperatively and immediately and 6 months postoperatively were used to measure the volume of the bone grafting material using a three-dimensional image analysis software. The immediate postoperative volume of octacalcium phosphate was 95.3775 mm3 per piece of grafting material used. It was multiplied by the number of pieces used and converted to mL to determine the immediate postoperative volume. RESULTS: The mean resorption values of carbonate apatite and octacalcium phosphate were 12.7 ± 3.6% and 17.3 ± 3.9%, respectively. A significant difference in the amount of resorption of the two bone replacement materials was observed (P = 0.04). CONCLUSIONS: The results of this study indicate that both bone substitute materials tend to resorb. The two bone grafting materials that are currently medically approved in Japan have not been in the market for a long time, and their long-term prognosis has not yet been reported. Further clinical data are warranted.


Assuntos
Substitutos Ósseos , Fosfatos de Cálcio , Levantamento do Assoalho do Seio Maxilar , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Substitutos Ósseos/uso terapêutico , Apatitas , Carbonatos
2.
Materials (Basel) ; 16(9)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37176189

RESUMO

Polylactic acid (PLA) has gained considerable attention as an alternative to petroleum-based materials due to environmental concerns. We fabricated implant models with fused filament fabrication (FFF) 3D printers using PLA, and the accuracies of these PLA models were compared with those of plaster models made from silicone impressions and resin models made with digital light processing (DLP). A base model was obtained from an impact-training model. The scan body was mounted on the plaster, resin, and PLA models obtained from the base model, and the obtained information was converted to stereolithography (STL) data by the 3D scanner. The base model was then used as a reference, and its data were superimposed onto the STL data of each model using Geomagic control. The horizontal and vertical accuracies of PLA models, as calculated using the Tukey-Kramer method, were 97.2 ± 48.4 and 115.5 ± 15.1 µm, respectively, which suggests that the PLA model is the least accurate among the three models. In both cases, significant differences were found between PLA and gypsum and between the PLA and resin models. However, considering that the misfit of screw-retained implant frames should be ≤150 µm, PLA can be effectively used for fabricating implant models.

3.
Dentomaxillofac Radiol ; 52(5): 20220352, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37192041

RESUMO

OBJECTIVES: This study aimed to evaluate the prognostic treatment outcome of non-operative management of medication-related osteonecrosis of the jaw (MRONJ), particularly regarding the relationship between image findings and treatment outcomes. METHODS: This single-center, retrospective observational study included patients with MRONJ who were conservatively treated between 2010 and 2020. All patients were evaluated in terms of MRONJ treatment outcomes, time to healing, and prognostic factors, including sex, age, underlying disease, antiresorptive drug type, discontinuation of antiresorptive treatment, chemotherapy, corticosteroid treatment, diabetes mellitus, location of MRONJ, clinical stage of MRONJ, and computed tomography image findings. RESULTS: The complete healing rate among the patients was 68.5%. Cox proportional hazards regression analysis revealed that "Sequestrum formation" on the internal texture (hazard ratio = 3.66; 95% confidence interval, 1.30-10.29; P =.014) and chemotherapy (hazard ratio = 0.41; 95% confidence interval, 0.18-0.95; P =.037) were significantly associated with treatment outcome. The median time to healing in patients with "Sequestrum formation" on the internal texture (4.4 months) was significantly shorter than the median time to healing in those marked with "Sclerosis" or "Normal" (35.5 months; P <.001) and "Lytic changes with sclerosis" (14.5 months; P =.015). CONCLUSIONS: The image findings on the internal texture of the lesions at the initial examination and chemotherapy were associated with the treatment outcomes of nonoperative management of MRONJ. The image findings of "Sequestrum formation" were associated with lesions taking a short time to heal and better outcomes, whereas "Sclerosis" and "Normal" were associated with lesions with longer healing times.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Humanos , Conservadores da Densidade Óssea/efeitos adversos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/terapia , Resultado do Tratamento , Estudos Retrospectivos , Prognóstico , Difosfonatos/efeitos adversos
4.
Materials (Basel) ; 16(7)2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37048914

RESUMO

Based on the hypothesis that the fabrication of dental models using fused deposition modeling and poly-lactic acid (PLA), followed by recycling and reusing, would reduce industrial waste, we aimed to compare the accuracies of virgin and recycled PLA models. The PLA models were recycled using a crusher and a filament-manufacturing machine. Virgin PLA was labeled R, and the first, second, and third recycles were labeled R1, R2, and R3, respectively. To determine the accuracies of the virgin and reused PLA models, identical provisional crowns were fitted, and marginal fits were obtained using micro-computed tomography. A marginal fit of 120 µm was deemed acceptable based on previous literature. The mesial, distal, buccal, and palatal centers were set at M, D, B, and P, respectively. The mean value of each measurement point was considered as the result. When comparing the accuracies of R and R1, R2, and R3, significant differences were noted between R and R3 at B, R and R2, R3 at P, and R and R3 at D (p < 0.05). No significant difference was observed at M. This study demonstrates that PLA can be recycled only once owing to accuracy limitations.

5.
J Prosthodont Res ; 67(1): 144-149, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35466158

RESUMO

Purpose We considered the possibility of reducing industrial waste by fabricating and reusing dental models prepared using a fused deposition modeling (FDM) 3D printer and polylactic acid (PLA) filaments. The purpose of this study was to verify the accuracy of models fabricated using FDM and PLA.Methods The same provisional crown was used to check the marginal fit on PLA models prepared using an intraoral scanner (IOS) and FDM, plaster models made with silicone impression material and plaster, and resin models prepared using an IOS and stereolithography apparatus (SLA) 3D printer. The marginal fit was measured using micro-computed tomography at four points on the tooth: the buccal center (B), palatal center (P), mesial center (M), and distal center (D) points.Results At point B, the marginal gaps were 118 ± 21.7, 62 ± 16.4, and 50 ± 26.5 µm for the PLA, resin, and plaster models, respectively, with a significant difference between the PLA model and the other two. However, the marginal gap at all other measurement points was not significantly different between the models (P > 0.05).Conclusions We compared the accuracy of the models fabricated using the FDM, SLA, and conventional methods. The combination of FDM and PLA filaments showed no significant differences from the other models, except at point B, indicating its usefulness. Therefore, FDM and PLA may become necessary materials for dental treatment in the future.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Microtomografia por Raio-X , Impressão Tridimensional , Poliésteres , Coroas
6.
Sci Rep ; 12(1): 18387, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319854

RESUMO

Currently, implants are utilized clinically for bone transplant procedures. However, if infectious osteomyelitis occurs at implant sites, removal of bacteria can be challenging. Moreover, altered blood flow at peri-implant infectious sites can create an anaerobic environment, making it more difficult to treat infection with antibiotics. Thus, it would be beneficial if implants could be modified to exhibit antibacterial activity, even in anaerobic conditions. Here, we show antibacterial activity of silver ions coated on titanium rods, even against the anaerobic bacteria Porphyromonas gingivalis (P. gingivalis), both in vitro and in vivo. Specifically, we implanted silver-coated or control uncoated titanium rods along with P. gingivalis in mouse femoral bone BM cavities and observed significantly inhibited P. gingivalis infection with silver-coated compared with non-coated rods, based on in vivo bio-imaging. Osteonecrosis by infectious osteomyelitis and elevation of the inflammatory factors C-reactive protein and IL-6 promoted by P. gingivalis s were also significantly reduced in the presence of silver-coated rods. Overall, our study indicates that silver ion coating of an implant represents a therapeutic option to prevent associated infection, even in anaerobic conditions or against anaerobic bacteria.


Assuntos
Antibacterianos , Bactérias Anaeróbias , Materiais Revestidos Biocompatíveis , Implantes Experimentais , Osteomielite , Prata , Animais , Camundongos , Antibacterianos/farmacologia , Bactérias Anaeróbias/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Íons/farmacologia , Osteomielite/microbiologia , Osteomielite/prevenção & controle , Prata/farmacologia , Titânio/química , Porphyromonas gingivalis/efeitos dos fármacos , Implantes Experimentais/efeitos adversos , Implantes Experimentais/microbiologia , Fêmur , Proteína C-Reativa
7.
BMC Oral Health ; 22(1): 286, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35836169

RESUMO

BACKGROUND: Several devices have been developed to measure implant-bone stability as an indicator of successful implant treatment; these include Osstell®, which measures the implant stability quotient (ISQ), and the more recent AnyCheck®, which relies on percussion for the implant stability test (IST). These devices make it possible to measure implant stability. However, no studies have compared the performance of AnyCheck® and Osstell® (i.e., IST and ISQ values) in clinical practice. Therefore, this study aimed to determine the correlation between primary and secondary implant stability using the Osstell® and AnyCheck® devices. METHODS: Ten patients (7 women; age [mean ± standard deviation]: 49.1 ± 13.3 years) with partially edentulous jaws who received a total of 15 implants were included. IST (AnyCheck®) and ISQ (Osstell®) values were measured immediately after implantation and at 1, 2, 3, 4, and 6 weeks post-implantation. Each measurement was performed three times, and the average value was used as the result. The correlation between measurements obtained using the two devices was determined using Spearman's rank correlation coefficient. RESULTS: The IST values ranged from 79.1 ± 2.87 to 82.4 ± 2.65. The ISQ values ranged from 76.0 ± 2.8 to 80.2 ± 2.35. Spearman's rank correlation coefficient was r = 0.64 immediately after implantation, r = 0.29 at 1 week, r = 0.68 at 2 weeks, r = 0.53 at 3 weeks, r = 0.68 at 4 weeks, and r = 0.56 at 6 weeks. A positive correlation was found in all cases, except at week 1 when the correlation was weak; the IST and ISQ values decreased the most during the first postoperative week and increased during the second week. The IST values were also slightly higher at all measurement points. CONCLUSION: The ability to assess implant stability without removing the abutment during healing is essential for determining the timing of loading without the risk of bone resorption. The results of this study suggest that AnyCheck® is useful for determining primary and secondary implant stability.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Adulto , Osso e Ossos , Implantação Dentária Endóssea/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Osseointegração , Percussão , Vibração
8.
Sci Rep ; 12(1): 19, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34997043

RESUMO

Invasive dental treatment such as tooth extraction following treatment with strong anti-bone resorptive agents, including bisphosphonates and denosumab, reportedly promotes osteonecrosis of the jaw (ONJ) at the extraction site, but strategies to prevent ONJ remain unclear. Here we show that in mice, administration of either active vitamin D analogues, antibiotics or anti-inflammatory agents can prevent ONJ development induced by tooth extraction during treatment with the bisphosphonate zoledronate. Specifically, tooth extraction during treatment with zoledronate induced osteonecrosis in mice, but administration of either 1,25(OH)2D3 or ED71, both active vitamin D analogues, significantly antagonized osteonecrosis development, even under continuous zoledronate treatment. 1,25(OH)2D3 or ED71 administration also significantly inhibited osteocyte apoptosis induced by tooth extraction and bisphosphonate treatment. Administration of either active vitamin D analogue significantly inhibited elevation of serum inflammatory cytokine levels in mice in response to injection of lipopolysaccharide, an infection mimetic. Furthermore, administration of either anti-inflammatory or antibiotic reagents significantly blocked ONJ development following tooth extraction and zoledronate treatment. These findings suggest that administration of active vitamin D, anti-inflammatory agents or antibiotics could prevent ONJ development induced by tooth extraction in patients treated with zoledronate.


Assuntos
Antibacterianos/administração & dosagem , Anti-Inflamatórios/administração & dosagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/prevenção & controle , Extração Dentária/efeitos adversos , Vitamina D/administração & dosagem , Ácido Zoledrônico/efeitos adversos , Animais , Apoptose/efeitos dos fármacos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/sangue , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Citocinas/sangue , Difosfonatos/efeitos adversos , Feminino , Humanos , Camundongos Endogâmicos C57BL , Osteócitos/citologia , Osteócitos/efeitos dos fármacos , Vitamina D/análogos & derivados
9.
J Med Case Rep ; 15(1): 599, 2021 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-34922609

RESUMO

BACKGROUND: Peripheral ossifying fibroma is an inflammatory or reactive hyperplasia of the gingiva that is usually small. It is formed by hard tissue in fibrous tissue, and the name "neoplastic lesion" has tended to be used frequently in Europe and America. Clinically, peripheral ossifying fibromas are painless, solitary, exophytic, sessile, or pedunculated and more frequently found in females than in males. To the best of our knowledge, there have been no reports of malignant cases. We herein report the case of giant peripheral ossifying fibroma with squamous cell carcinoma. CASE PRESENTATION: The patient was an 83-year-old Japanese woman who visited our hospital with a gingival massive mass. She was referred to us for an examination and treatment because it was difficult to perform tracheal intubation for surgery of sigmoid colon cancer at another hospital. The mass measured 83 × 58 × 35 mm, and it protruded to the extra-oral region from the right maxillary premolar alveolar region. Panoramic X-ray revealed the shadow of the mass in the right maxillary premolar region, which included some hard tissue. Computed tomography showed scattering calcified images in the mass. Magnetic resonance imaging was not performed because she had vertebral artery clips and screws in her forehead. Given the above findings, we performed a biopsy under local anesthesia. However, we were unable to diagnose absolutely whether the dysplastic squamous epithelia were pseudocarcinomatous hyperplasia of the gingiva or well-differentiated squamous cell carcinoma. Therefore, tumor resection was performed under general anesthesia. The histopathological diagnosis was peripheral ossifying fibroma with coincidental squamous cell carcinoma. There have been no signs of recurrence during follow-up as of 2 years after surgery. CONCLUSIONS: The etiology of giant peripheral ossifying fibroma with squamous cell carcinoma is still not definite. Therefore, careful observation is necessary. It needs to be examined by accumulation of more cases in the future. We herein report the case of giant peripheral ossifying fibroma coincidental squamous cell carcinoma.


Assuntos
Carcinoma de Células Escamosas , Fibroma Ossificante , Idoso de 80 Anos ou mais , Biópsia , Carcinoma de Células Escamosas/complicações , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/cirurgia , Feminino , Fibroma Ossificante/complicações , Fibroma Ossificante/diagnóstico por imagem , Fibroma Ossificante/cirurgia , Humanos , Hiperplasia , Masculino , Radiografia Panorâmica
10.
Oral Oncol ; 123: 105629, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34784507

RESUMO

OBJECTIVES: We aimed to evaluate the clinical value of an entire-circumferential intraoperative frozen section analysis (e-IFSA) for the complete resection of superficial squamous cell carcinoma (SCC) of the tongue. MATERIALS AND METHODS: A total 276 specimens from 51 patients with pT1-2, N0, mucosal or submucosal invasion SCC were analyzed to evaluate the diagnostic accuracy of the e-IFSA and the added value of the e-IFSA to iodine staining. The e-IFSA results were compared with the final histologic results obtained using permanent sections. All specimens for the e-IFSA were taken over the entire circumference 5 mm outside from the iodine unstained areas. The outline of the main resected specimen after taking these outer mucosal specimens were defined as the surgical margins determined by iodine staining alone. RESULTS: The e-IFSA results were in excellent agreement with final histological results (Cohen's kappa value: 0.85) and the e-IFSA showed high sensitivity (100%) and high negative predictive value (100%). The actual complete resection rate with an e-IFSA was 100% (51/51), and no patient required additional resection after surgery. In contrast, 10/51 patients (20%) patients showed residual atypical mucosal epithelium at or beyond the margin determined by iodine staining alone; this difference was statistically significant (P = 0.002). The 5-year local control rate and 5-year overall survival rate after this procedure were both 100%. CONCLUSION: An e-IFSA has additional value when performed in conjunction with iodine staining. An e-IFSA would be useful for achieving complete resection of superficial SCC of the tongue.


Assuntos
Carcinoma de Células Escamosas , Margens de Excisão , Neoplasias da Língua , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Epitélio/patologia , Secções Congeladas , Humanos , Estudos Retrospectivos , Língua/patologia , Língua/cirurgia , Neoplasias da Língua/patologia , Neoplasias da Língua/cirurgia
11.
BMC Oral Health ; 21(1): 464, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34556111

RESUMO

BACKGROUND: The use of intraoral scanners (IOS) has facilitated the use of digital workflows for the fabrication of implant-supported prostheses not only for single missing teeth, but also for multiple missing teeth. However, the clinical application of IOS and computer-aided design/manufacturing (CAD/CAM) in implant-supported prosthodontics remains unclear. This study aimed to compare the accuracy of digital and silicone impressions for single-tooth implants for bounded edentulous spaces and two-unit and three-unit implant-supported fixed dental prostheses for free-end edentulous spaces. METHODS: This study enrolled 30 patients (n = 10 for each of the three groups) with an average age of 61.9 years. Conventional silicone-based and digital IOS-based impressions were made for all patients, and the implant superstructures were fabricated. We measured the scan-body misfit and compared the accuracy of the impressions for single-unit, two-unit, and three-unit implant prostheses with a bounded edentulous space by superimposing the standard triangulated language (STL) data obtained from IOS over the STL data of the plaster model used for final prosthesis fabrication. The scan bodies of the superimposed single-molar implant, two-unit implant prosthesis without teeth on the mesial side, two-unit implant prosthesis without teeth on the distal side, three-unit implant prosthesis without teeth on the mesial side, and three-unit implant prosthesis without teeth on the distal side were designated as A, B1, B2, C1, and C2, respectively. The misfit for each scan body was calculated and the accuracies were compared using the Tukey-Kramer method. RESULTS: The average scan-body misfit for conditions A, B1, B2, C1, and C2 was 40.5 ± 18.9, 45.4 ± 13.4, 56.5 ± 9.6, 50.7 ± 14.9, and 80.3 ± 12.4 µm, respectively. Significant differences were observed between the accuracies of A and B2, A and C2, and C1 and C2 (P < 0.001). CONCLUSIONS: IOS and CAD/CAM can find clinical applications for implant-supported prostheses of up to three units for a bounded edentulous saddle. The use of IOS could render implant treatment easier, benefiting both the surgeons and patients. Prosthesis maladjustment may lead to peri-implantitis and prosthetic fracture. Therefore, further validation of the accuracy of IOS impressions is required in patients with multiple missing teeth in long-span implant prostheses.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Pessoa de Meia-Idade , Silicones
13.
Artigo em Inglês | MEDLINE | ID: mdl-34205936

RESUMO

Intravenous cannulation is an invasive procedure that causes stress, anxiety, and pain for many patients. A recent animal study found that exposure to green light induced antinociceptive and anxiolytic effects. This study examined whether green color exposure reduced stress, anxiety, and pain during peripheral intravenous cannulation (PIC) for sedation in dental patients. In this controlled clinical trial, 24 patients (mean age 40.9 years) were randomized to wear clear glasses or green-colored glasses for 15 min before PIC on two separate days in a cross-over manner. The primary outcome measures were salivary alpha-amylase (sAA) activity and stress-related hemodynamic changes, and the secondary outcome measures were the visual analog scale anxiety (VAS-A) and pain (VAS-P) scores during PIC. The sAA level in the clear group significantly increased during PIC compared with baseline, but did not increase in the green group. Median VAS-P scores during PIC were lower in the green group than in the clear group (VAS-P, 17.0 vs. 50.0). Green color exposure with glasses significantly reduced stress and pain during PIC without any adverse effects. This simple, safe, and effective method may be useful during painful medical procedures.


Assuntos
Cateterismo Periférico , Dor , Adulto , Ansiedade , Humanos , Manejo da Dor , Medição da Dor
14.
Int J Implant Dent ; 7(1): 24, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33754242

RESUMO

BACKGROUND: In locations where the alveolar bone height is low, such as at the maxillary molars, implant placement can be difficult, or even impossible, without procedures aimed at generating new bone, such as sinus lifts. Various types of bone graft materials are used after a sinus lift. In our study, a three-dimensional image analysis using a volume analyzer was performed to measure and compare the volume of demineralized bovine bone mineral (Bio-Oss®) and carbonate apatite (Cytrans®) after a sinus lift, as well as the amount of bone graft material resorption. Patient data were collected from cone-beam computed tomography images taken before, immediately following, and 6 months after the sinus lift. Using these images, both the volume and amount of resorption of each bone graft material were measured using a three-dimensional image analysis system. RESULTS: The amount of bone resorption in the Bio-Oss®-treated group was 25.2%, whereas that of the Cytrans®-treated group was 14.2%. A significant difference was found between the two groups (P < 0.001). CONCLUSIONS: Our findings indicate that the volume of bone resorption was smaller in the Cytrans®-treated group than in the Bio-Oss®-treated group, suggesting that Cytrans® is more promising for successful implant treatments requiring a sinus lift.


Assuntos
Substitutos Ósseos , Imageamento Tridimensional , Animais , Apatitas , Substitutos Ósseos/uso terapêutico , Bovinos , Humanos , Seio Maxilar/diagnóstico por imagem , Minerais
15.
Brain Sci ; 11(2)2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33499207

RESUMO

Postoperative pain and consequent inflammatory responses after tissue incision adversely affects many surgical patients due to complicated mechanisms. In this study, we examined whether activation of protease-activated receptor 2 (PAR-2), which is stimulated by tryptase from mast cells, elicits nociception and whether the PAR-2 antagonist could reduce incisional nociceptive responses in vivo and in vitro. The effects of a selective PAR-2 antagonist, N3-methylbutyryl-N-6-aminohexanoyl-piperazine (ENMD-1068), pretreatment on pain behaviors were assessed after plantar incision in rats. The effects of a PAR-2 agonist, SLIGRL-NH2, on nociception was assessed after the injection into the hind paw. Furthermore, the responses of C-mechanosensitive nociceptors to the PAR-2 agonist were observed using an in vitro skin-nerve preparation as well. Intraplantar injection of SLIGRL-NH2 elicited spontaneous nociceptive behavior and hyperalgesia. Local administration of ENMD-1068 suppressed guarding behaviors, mechanical and heat hyperalgesia only within the first few hours after incision. SLIGRL-NH2 caused ongoing activity in 47% of C-mechanonociceptors in vitro. This study suggests that PAR-2 may support early nociception after incision by direct or indirect sensitization of C-fibers in rats. Moreover, PAR-2 may play a regulatory role in the early period of postoperative pain together with other co-factors to that contribute to postoperative pain.

16.
Int J Implant Dent ; 7(1): 2, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33432526

RESUMO

BACKGROUND: Implant treatment using guided surgery is becoming widespread in clinical dental practice. Furthermore, the development of digital technology has enabled the use of intraoral scanners (IOSs) to fabricate surgical guide plates. The objective of this study was to compare the accuracy of guided surgery using the silicone impression method with a three-dimensional (3D) scanner and the digital impression method with IOS for one side of the mandibular free end. In addition, we compared the accuracy of tooth-supported vs tooth/mucosa-supported surgical guide plates. RESULTS: The accuracy of the tooth-supported surgical guide plate using the new IOS method instead of the method of obtaining impressions with conventional silicone resulted in better measurements of 3D deviation at the crest, 3D deviation at the apex, and angular deviation. In terms of the accuracy of the tooth/mucosa-supported surgical guide plate, there were no significant differences in all measurements. The surgical guide plate using an IOS and the tooth/mucosa-supported surgical guide plate may enable more accurate guided surgery. CONCLUSION: Tooth/mucosa-supported guided surgery involving preparation with an IOS may result in more accurate implant surgery.


Assuntos
Desenho Assistido por Computador , Silício , Placas Ósseas , Mandíbula/diagnóstico por imagem , Silicones
17.
Int J Med Robot ; 17(2): e2205, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33207394

RESUMO

BACKGROUND: Microsurgery requires high skills for suturing using fragile threads, often within narrow surgical fields. Precise tension is required for good healing and to avoid the risk of thread breakage. METHODS: To meet the demands, we developed a novel assist robot utilizing high-precision sensorless haptic technology. The robot adopts a cable-driven mechanism to maintain a distance from the surgical area and enhances compatibility with surgical equipment such as microscopes. The robot performance was verified through in vitro and in vivo experiments using a rat model. RESULTS: The realization of precise tension control was confirmed in both experiments. In particular, in the in vivo experiments, the developed robot succeeded to produce a knot with an accurate tension of 0.66% error. CONCLUSIONS: The developed robot can realize to control traction force precisely. This technology might open up the window for a full assist robot for microsurgery with haptic feeling.


Assuntos
Microcirurgia , Animais , Desenho de Equipamento , Ratos , Procedimentos Cirúrgicos Robóticos , Software , Tração , Interface Usuário-Computador
18.
Biochem Biophys Res Commun ; 534: 395-400, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33246558

RESUMO

Chronic postsurgical pain (CPSP) is a serious issue for many postoperative patients. Though there are numerous treatment options for the prevention of CPSP, none of them is optimal as the mechanisms of the transition from acute to chronic postoperative pain have not been elucidated. Ketamine and opioids have been administered for chronic postoperative pain treatment but induce severe adverse reactions and/or physical dependency. Here, we examined whether pre-administration of the nonselective N-methyl-d-aspartate (NMDA) receptor antagonist magnesium sulfate attenuates CPSP behavior and alters the expression of glutamate ionotropic receptor NMDA type subunit 1a (Grin1 mRNA) in a rat skin/muscle incision and retraction (SMIR) model. We assessed the effects of a single subcutaneous magnesium sulfate injection on nociceptive behaviors including guarding pain, mechanical hyperalgesia, and heat hypersensitivity in rats after SMIR surgery. We used reverse transcription-quantitative PCR (RT-qPCR) to evaluate Grin1 mRNA expression in the dorsal horn of the spinal cord on postoperative day 14. Compared with the vehicle, magnesium sulfate administration before SMIR surgery reduced mechanical hyperalgesia for 17 d Grin1 gene expression was significantly higher on the ipsilateral side than the contralateral side (P = 0.001) on postoperative day 14. The magnesium sulfate injection prevented Grin1 mRNA upregulation in the spinal cord dorsal horn. A single magnesium sulfate injection mitigated SMIR-induced mechanical hyperalgesia possibly by modulating Grin1 expression. Preoperative magnesium sulfate administration could prove to be a simple and safe CPSP treatment.


Assuntos
Analgésicos/administração & dosagem , Sulfato de Magnésio/administração & dosagem , Dor Pós-Operatória/prevenção & controle , Animais , Modelos Animais de Doenças , Esquema de Medicação , Expressão Gênica/efeitos dos fármacos , Hiperalgesia/genética , Hiperalgesia/fisiopatologia , Hiperalgesia/prevenção & controle , Injeções Subcutâneas , Masculino , Dor Pós-Operatória/genética , Dor Pós-Operatória/fisiopatologia , Período Pré-Operatório , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Receptores de N-Metil-D-Aspartato/genética , Medula Espinal/efeitos dos fármacos , Medula Espinal/metabolismo , Regulação para Cima/efeitos dos fármacos
19.
J Bone Miner Metab ; 39(3): 372-384, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33200254

RESUMO

INTRODUCTION: Osteonecrosis of the jaw (ONJ) occurring after invasive dental treatment often adversely affects patients' activities of daily living. Long-term administration of strong anti-bone resorptive agents such as bisphosphonates prior to invasive dental treatment is considered an ONJ risk factor; however, pathological mechanisms underlying ONJ development remain unclear. MATERIALS AND METHODS: We developed an ONJ mouse model in which a tooth is extracted during treatment with the bisphosphonate zoledronate. RESULTS: We observed induction of apoptosis in osteocytes, resulting in formation of empty lacunae in jaw bones at sites of tooth extraction but not in other bones of the same mice. We also observed elevated levels of inflammatory cytokines such as TNFα, IL-6 and IL-1 in jaw bone at the extraction site relative to other sites in zoledronate-treated mice. We also report that treatment in vitro with either zoledronate or an extract from Porphyromonas gingivalis, an oral bacteria, promotes expression of inflammatory cytokines in osteoclast progenitor cells. We demonstrate that gene-targeting of either TNFα, IL-6 or IL-1 or treatment with etanercept, a TNFα inhibitor, or a neutralizing antibody against IL-6 can antagonize ONJ development caused by combined tooth extraction and zoledronate treatment. CONCLUSIONS: Taken together, the cytokine storm induced by invasive dental treatment under bisphosphonate treatment promotes ONJ development due to elevated levels of inflammatory cytokine-producing cells. Our work identifies novel targets potentially useful to prevent ONJ.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/patologia , Citocinas/metabolismo , Mediadores da Inflamação/metabolismo , Extração Dentária/efeitos adversos , Ácido Zoledrônico/efeitos adversos , Animais , Apoptose/efeitos dos fármacos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/microbiologia , Conservadores da Densidade Óssea/efeitos adversos , Transdiferenciação Celular/efeitos dos fármacos , Síndrome da Liberação de Citocina/complicações , Modelos Animais de Doenças , Feminino , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Macrófagos/patologia , Camundongos Endogâmicos C57BL , Modelos Biológicos , Osteoclastos/efeitos dos fármacos , Osteoclastos/patologia , Osteócitos/efeitos dos fármacos , Osteócitos/patologia , Osteogênese/efeitos dos fármacos , Porphyromonas gingivalis/fisiologia , Fatores de Risco
20.
Anesth Prog ; 67(3): 158-163, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32992337

RESUMO

Inflammatory bowel disease (IBD) is a group of chronic inflammatory disorders of the gastrointestinal tract including ulcerative colitis (UC) and Crohn's disease. Pain management can be challenging in patients with IBD because there are limitations on the use of analgesics. Use of nonsteroidal anti-inflammatory drugs is not recommended in patients with IBD because there is risk of relapse of IBD and an overall increase in disease activity. Opioids, although frequently used for treating severe acute pain, can have additional risks and complications in patients with IBD such as ileus, toxic megacolon, and narcotic bowel syndrome. Furthermore, little information is available in the literature on pain management in these patients undergoing noncolorectal surgery. This report describes 2 patients with UC in whom postoperative pain following oral and maxillofacial surgery was managed by intravenous patient-controlled analgesia with pentazocine. Apart from the development of acute dystonia in 1 case that was likely due to the use of droperidol for prevention of postoperative nausea and vomiting, postoperative pain was well controlled by pentazocine in both patients without any complications or UC exacerbations.


Assuntos
Colite Ulcerativa , Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Dor Pós-Operatória , Pacientes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...